
Last night, I downloaded EditPad Pro (from download.com). Oh well, I still like the simplicity of my approach, and I use it on a daily basis, so. Just Great Software EditPad Pro C compiler, standalone or as part of Visual Studio (only if you want to compile this project) UPDATE: It turns out EditPad Pro 7 does have a Find on Disk function, which basically surpasses my app in almost every aspect. Such a snippet can be a word, phrase, three. It has everything you could want in a text editor: huge file support (4GB+), spell check, projects, search on disk, FTP and SFTP, hexadecimal mode, syntax coloring with bracket and tag matching, file navigator showing the structure of your files, running external tools and scripts, file comparison, and more.Installing the Borland Database Engine with DeployMaster Installing the BDE and Creating AliasesEditPad Pro's Clip Collection makes it easy to keep a list of text snippets at your fingertips, ready to be inserted into the file's you're editing. EditPad Pro is EditPad Lite's big brother.

Important: If you are using the sample DeployBDE support DLL, you must turn off the option to call DllRegisterServer! The DeployBDE sample support DLL will call it, and if you let DeployMaster call it also, the BDE will be installed twice.3. Add the file BDEInst.dll to the %APPFOLDER% folder in your DeployMaster setup package. By letting this DLL do the dirty work, we make sure that the BDE is properly installed.2. This DLL contains the Borland Database Engine along with a self-extracting installation program created by Borland. Use a program like WinZIP to extract the file BDEInst.dll from the CAB file.

You can request help on these routines by putting the text cursor on them in the Delphi IDE and pressing F1.First, DbiInit is called to load the BDE. This is done by calling a few low-level routines from the BDE unit that ships with Delphi. When the routine returns, BDEInst.dll is unloaded and deleted since it no longer serves any purpose.After installing the BDE, you can create BDE aliases in the FinishDeployment routine. This routine will take care of the entire BDE installation. The FinishDeployment procedure from DeployBDE.dll will load BDEInst.dll and call its DllRegisterServer routine. Then, DeployMaster will call the FinishDeployment procedure in the support DLL you included with your package.
Example: SQL-Links drivers for Interbase: SQLINT32.DLL (Interbase driver) and SQL_INT.CNF (BDE-config file for Interbase driver)2. It contains information on what files you need to redistribute to support SQL Databases. Read the file bdedeploy.txt in the BDE folder on your computer. SQL Links is required if you use the BDE to communicate with a SQL database such as InterBase or MS SQL Server.You could try to do the following, but I have not tested this myself:1. SQL LinksThe method for installing the BDE described above does not install SQL Links.
Add all these keys to the Registry tab in DeployMaster or modify the BDEInst.dll to create them.3. Interbase: subkey “INTRBASE”). Select the subkey matching your Database driver (e.g.
UninstallUninstalling the BDE through the DeployMaster uninstaller is not possible.Since there is no way to figure out how many applications on the user’s system depend on the BDE, uninstalling it is probably not desirable anyway.If you want to uninstall your BDE aliases, you can let your own application do so. Since this installation is only done in FinishDeployment(), you should let DeployMaster install those files in %APPFOLDER% (where it is also installing BDEInst.dll) and then move the files into the correct position in the FinishDeployment() DLL routine, after the BDE has been installed. These should be installed into the folder listed in HKEY_LOCAL_MACHINE\Software\Borland\Database Engine\DLLPATH after the BDE has been installed.
Editpad Pro Compile Code Of 1
If the user tells the installer to continue regardless, the BDE will be installed correctly.To fix this, you can download an unofficial patch BdeInstDiskSpacePatch.zip. This causes the BDE installer to incorrectly report that there’s not enough free disk space if your hard disk has more than 2 GB of free space. One issue that has cropped up is that the BDE installer uses a signed 32-bit integer to check for free disk space. Faulty Free Disk Space CheckThe BDE was discontinued by Borland many years ago. Terminating with an exit code of 1 is important, otherwise the uninstaller will think the uninstallation should be canceled.To remove an alias, use DbiInit, DbiDeleteAlias, DbiCfgSave and DbiExit like in the DeployBDE.dll used for creating them. Modify your application so that when the uninstall parameter is present, it will remove the alias and terminate with Halt(1).
Since the BDE uses only a few megabytes of disk space, any modern PC should have enough free space. The patch will make a one-byte change to BdeInst.dll that disables the free disk space check. Zip archive, place it into the same directory as BdeInst.dll, and run.
